模拟放射性污染土壤样品中147Pm的分离及液闪测量

    Separation and Liquid Scintillation Analysis of 147Pm in Radioactive Polluted Soil Sample

    • 摘要: 本工作针对受乏燃料污染的环境土壤样品,研究了Pm的分离纯化方法,建立了147Pm的分析流程,流程收率大于70%,对主要干扰核素的去污因子大于103。同时,通过147Pm标准源对效率示踪法测量结果进行验证,测量值与推荐值相对偏差小于0.5%。将该方法应用于模拟样品分析,其结果与147Nd测量推荐值的相对偏差小于2%。

       

      Abstract: Focused on the environmental soil sample contaminated by spent fuel, a Pm separation procedure was established with a recovery greater than 70% for Pm and the decontamination factor greater than 103 for the interference elements. The activity of 147Pm standard sample was determined by liquid scintillation counting (LSC) with the efficiency tracing method (ETM), giving a relative deviation less than 0.5%. The analysis method of 147Pm was validated for simulated polluted soil sample (prepared by mixing the spent fuel with environmental soil) and the results are in good agreement with the referenced data with a relative deviation of 2%.

       

    /

    返回文章
    返回