高效液相色谱法同时测定镥177Lu氧奥曲肽注射液中两种稳定剂的含量

    Simultaneous Determination of Two Stabilizers Content in Lutetium177Lu Oxodotreotide Injection by High-Performance Liquid Chromatography

    • 摘要: 为建立高效液相色谱法(HPLC)测定镥177Lu氧奥曲肽注射液中稳定剂(龙胆酸、维生素C)的含量,采用十八烷基硅烷键合有机杂化硅胶填充的色谱柱(4.6 mm×250 mm×5 μm),以0.82 g/L醋酸钠溶液(用冰醋酸调pH至3.50)和甲醇为流动相,串联紫外-可见分光检测器(检测波长为295 nm)与放射性流量检测器,柱温为25 ℃,进样体积为5 μL,运行20.0 min,1.00 mL/min进行梯度淋洗,可有效地将龙胆酸和维生素C分离。龙胆酸和维生素C分别在0~1.50 g/L和 0~30.0 g/L质量浓度范围内线性关系良好,相关系数r分别为1.000和0.998;改变柱温、流速、流动相pH值等色谱条件时,样品溶液中维生素C和龙胆酸含量的相对标准偏差均满足≤2.0%的要求;龙胆酸的回收率满足90%~108%的要求,维生素C回收率满足92%~105%的要求。该方法简便、快速、灵敏、准确,可用于镥177Lu氧奥曲肽注射液中龙胆酸和维生素C含量的准确测定,为该类药物的工艺过程优化提供了指导作用。

       

      Abstract: A high-performance liquid chromatography(HPLC) was established for the determination of stabilizer(gentisic acid, vitamin C) content in lutetium177Lu oxodotreotide injection. The liquid chromatographic parameters were finally confirmed by the optimization experiments of the chromatographic column, mobile phase, elution gradient and UV wavelength. The chromatographic column(4.6 mm×250 mm×5 μm) filled with octadecylsilane bonded organic hybrid silica gel was used, and the mobile phase was 0.82 g/L sodium acetate solution(pH was adjusted to 3.50 with glacial acetic acid) and methanol(gradient elution). The detector system was ultra-violet visible spectroscopic detector(detection wavelength was 295 nm) and radioactive flow detector connnected in series. The column temperature was 25 ℃, the injection volume was 5 μL, the running time was 20.0 min, and the flow rate was 1.00 mL/min with gradient elution. The method can effectively separate gentisic acid and vitamin C, and the resolution meets the requirement of greater than 1.5. The linear ranges of gentisic acid and vitamin C are 0-1.50 g/L and 0-30.0 g/L, respectively. The correlation coefficient r are 1.000 and 0.998, respectively. When the chromatographic conditions of column temperature, flow rate and mobile phase pH are changed, the relative standard deviation(sr) of vitamin C and gentisic acid in the sample solution are 1.62% and 1.16%(n=9) respectively, meet the requirement of less than 2.0%. The sr of the retention and content of gentisic acid in six samples are 0.10% and 0.13%, respectively. The sr of the retention and content of vitamin C in six samples are 0.06% and 0.19%, respectively. The sr of the retention and content of gentisic acid in twelve samples are 0.18% and 0.30%, respectively. The sr of the retention and content of vitamin C in twelve samples are 0.10% and 1.49%, respectively. The above sr results all meet the requirement of less than 2.0%. The rate of recovery of gentisic acid meets the requirement of 90%-108%, and the rate of recovery of vitamin C meets the requirement of 92%-105%. This method can accurately determine the contents of gentianic acid and vitamin C without diluting the sample, improving measurement accuracy and reducing radiation dose. The method has good durability, accuracy, and precision. The HPLC method is simple, rapid, sensitive, and accurate, which can be used for the accurate determination of gentisic acid and vitamin C in lutetium177Lu oxodotreotide injection, and provide guidance for the optimization of the process of these drugs.

       

    /

    返回文章
    返回