~(68)Ge-~(68)Ga发生器的研制——~(68)Ge-~(68)Ga发生器的稳定性研究

    • 摘要: 研究了不同时间间隔淋洗68Ge-68Ga发生器时,68Ga的淋洗曲线、淋洗效率、68Ge的穿透率、流出液中的Sn含量及温度对68Ga淋洗效率的影响。实验结果表明,用1mol/LHCl淋洗以SnO2为吸附剂的68Ge-68Ga发生器,每次淋洗间隔时间1-14天不等,历经半年时间的淋洗,68Ge的穿透率保持在10-7数量级,淋洗液中的Sn含量保持在4×10-7以下。68Ga淋洗曲线的形状未发生变化,68Ga的淋洗效率为55%—75%,淋洗时间间隔变化不影响淋洗效率,温度对淋洗效率有较大影响。

       

      Abstract: PREPARATION AND STUDY OF 68Ge 68Ga GENERATOR——STUDY OF THE STABILITY OF 68Ge 68Ga GENERATORTang Qiming Zhao Guizhi Long Weizhong Li Dakang(Department of Isotope,China Institute of Atomic Energy,P.O.Box 275(43),Beijing 102413)ABSTRACTThe stability of the isotope generator of 68Ge 68Ga,including the elution curve of 68Ga,elution efficiency of 68Ga,breakthrough of 68Ge and the concentration of Sn in the elute are studied.The generator is eluted by 1 mol/L HCl at varying intervals from one day to fourteen days.The adsorbent of the generator is SnO2.Based on the elutions in a half year,these data are obtained:breakthrough of 68Ge is in the order of 10-7,the concentration of Sn in the elute is less than 4×10-7,the shape of the elution curve of 68Ga is unchanged,but the elution efficiency of 68Ga is varied from 55% to 75%. It is found that the varying elution interval does not change the elution efficiency of 68Ga and varying elution efficiency is caused by varying temperature.Key words 68Ge 68Ga Generator Stability Elution efficiency Breakthrough

       

    /

    返回文章
    返回