脉冲熔融红外吸收法测定钽、钨涂层中的氧

    Determination of Oxygen Content in Ta, W Coats by Pulse MeltingIR Absorption

    • 摘要: 采用脉冲熔融红外吸收法测定钽、钨涂层中氧的质量分数。着重讨论了分析功率、助熔剂种类、坩埚类型、空白值及样品质量对测定结果的影响,制定出了钽、钨涂层中微量氧的分析方法。结果表明, 钽、钨涂层试样中氧的质量分数的相对标准偏差分别为2.94%, 6.01%(n=6), 回收率分别为93%~108%和92%~108%。

       

      Abstract: The determination of mass percentage of oxygen in tantalum and tungsten coats by pulse meltinginfrared absorption spectrometry is described in this paper with emphasis on the influence of the electric power for analysis, fusing agent, crucible type, reagents and crucible blanks, and sample size on the determination results. Based on these experimental results a procedure for determination of trace oxygen in these coats is established. The procedure is examined with tantalum and tungsten coat samples and two reference materials. The results show that the relative standard deviations are 2.94% and 6.01%(n=6) for tantalum and tungsten coats and the recoveries are in the range of 93%-108% for the former and 92%-108% for the latter.

       

    /