含氚泵油表面活性剂复配法的测氚技术

    Determination of 3H in Tritiated Waste Pump Oil by LSC via Dispersion With Mixed Surfactants

    • 摘要: 为测量含氚废旧泵油的氚浓度,研究了表面活性剂十二烷基甜菜碱(BS-12)和脂肪醇聚氧乙烯醚(FEO)复配的表面化学性质和热力学性质,通过复配体系乳化泵油,并与液闪液形成分散体系达到测氚目的。结果表明,复配胶束浓度小于10-4 mol/L、BS-12与FEO复配体积比为6∶4、泵油测量体积小于0.012 mL、NaCl浓度为0.1 mol/L时具有稳定的测量结果。

       

      Abstract: In order to determine tritium in tritiated waste pump oil, surface chemical properties and thermodynamic functions of BS-12/FEO/H2O system were studied. Mixed system was obtained when oil and scintillation liquid added in it. The results show that when surfactant concentration is less than 10-4 mol/L, V(BS-12)∶ V(FEO) is 6∶4, oil volume added to 5 mL of Ultima Gold LLT cocktail is less than 0.012 mL, NaCl concentration is 0.1 mol/L, quite stable liquid scintillation counting rate can be obtained.

       

    /