MA Mei-hua, GAO Zhi-xing, TANG Xiu-zhang, ZHENG Zuo-xi, ZHU Xin-yan, ZHANG Yi, LIU Yu-xin. Laser Decontamination Research on Radioactive Simulated Specimens in Air[J]. Journal of Nuclear and Radiochemistry, 2017, 39(1): 69-71. DOI: 10.7538/hhx.2017.39.01.0069
    Citation: MA Mei-hua, GAO Zhi-xing, TANG Xiu-zhang, ZHENG Zuo-xi, ZHU Xin-yan, ZHANG Yi, LIU Yu-xin. Laser Decontamination Research on Radioactive Simulated Specimens in Air[J]. Journal of Nuclear and Radiochemistry, 2017, 39(1): 69-71. DOI: 10.7538/hhx.2017.39.01.0069

    Laser Decontamination Research on Radioactive Simulated Specimens in Air

    • The study on the laser decontamination parameters was carried on with the simulated radioactive specimens made by LLRW and using APEX laser. The efficiency of different laser parameters such as laser intensity, laser frequency, laser angle and laser scanning speed were investigated on the decontamination factor(DF), and then the optimized laser decontamination parameters were obtained. Using the optimized parameters, the laser decontamination was studied with the simulated stainless steel specimens by the laser decontamination equipment. The experimental results show that the DF is more than 200, and the peeling thickness on the stainless steel base is less than 20 μm.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint