DU Gui-rong, GUO Guo-long, WANG Chun-ye, LIU Yang, SUN Xiao-guang. Improve of Determination of Mn, Cr, Ni, Mo and Th in Uranium Dioxide Pallets[J]. Journal of Nuclear and Radiochemistry, 2017, 39(2): 179-182. DOI: 10.7538/hhx.2017.YX.2016021
    Citation: DU Gui-rong, GUO Guo-long, WANG Chun-ye, LIU Yang, SUN Xiao-guang. Improve of Determination of Mn, Cr, Ni, Mo and Th in Uranium Dioxide Pallets[J]. Journal of Nuclear and Radiochemistry, 2017, 39(2): 179-182. DOI: 10.7538/hhx.2017.YX.2016021

    Improve of Determination of Mn, Cr, Ni, Mo and Th in Uranium Dioxide Pallets

    • Uranium dioxide pallets were dissolved in HNO3. Mn, Cr, Th were determined by ICP-OES and Ni, Mo by GAAS after separation by TBP resins. U and Th were adsorbed in 3 mol/L HNO3 by TBP resins and Mn, Ni, Mo, Cr were received as solution A. Th was received as solution B after 8 mL dead volume. Solution A and B were steamed to nearly dry and then dissolve by dilute acid for measurement. The method is verified through reference material GBW04242. The measured values are in the confidence interval.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return