Treatment of Low-Level Wastewater of Pu Using Coagulationand Microfiltration Technological Process
-
Graphical Abstract
-
Abstract
The coagulation and microfiltration combined technological process (CMF) was used to treat the low-level radioactive 239Pu wastewater. This paper referred to the effect of correlation parameters on cleaning efficiency, such as the content of Fe2+and pH of the effluent. The results of test show that the removal efficiency is higher than 99.9% when the content of the Fe2+ is 3560 mg/L and pH of the effluent is between 6.5 and 9.0. The proof test of the 239Pu wastewater containing 238U and 241Am was done and the integrated experimental technological process is established. The results show that the α removed efficiency of 1 stage is 99.87%.
-
-