Sequential Separation Method of 79Se, 93Zr, and 107Pd From High Level Liquid Waste
-
Graphical Abstract
-
Abstract
A procedure including DMG resin column, silica gel column and Bis-Ⅱresin column was established to sequentially separate 79Se, 93Zr and 107Pd from high level liquid waste(HLLW). A simulated solution was prepared to test the procedure and 75Se, 95Zr and 109Pd were used as tracers. The recovery of Se is near to 90%, and that of Pd and Zr are more than 90%, and the decontamination factors of 90Sr, 137Cs and 152Eu are better than 103.
-
-